how does the incinerator works? the incinerator mainly for medical waste and animal waste treatment with oil/gas fired in the primary chamber with high temeprature and the secondary chamber fired the gas from the parimary chamber with higher temeprature average 1000-1200 or more to 1600 degree. afterburnning is smoke scrubber with dry or wet scrubber system. incinerator is top […]
HICLOVER incinerator exert the advantages and discard the disadvantages of the same kind of equipment at domestic and abroad. It is an unique and international advanced medical waste incineration equipment. The equipment is small size, high efficiency, reasonable process, leading technologies and a high harmless degree, ideal garbage treatment equipment for hospital, laboratory, hotel, station, etc. […]
Incinerator Items/Model HICLOVER TS30(PLC) HICLOVER TS50(PLC) HICLOVER TS100(PLC) Burn Rate (Average) 30-50 kg/hour 50-100 kg/hour 100-150 kg/hour Feed Capacity(Average) 60kg/feeding 100kg/feeding 350kg/feeding Control Mode PLC Automatic PLC Automatic PLC Automatic Primary Combustion Chamber 330L(0.33M3) 560L(0.56M3) 1810L(1.81M3) Internal Dimensions 75x75x60cm 100x80x70cm 165x110x100cm Secondary Chamber 180L 280L 660L Smoke Filter Chamber Yes Yes Yes […]
Smallest waste incinerator for small hospital average 10kgs per hour. with double(2) sets burner. Equipment Technical Specifications Model YD-10 Feed Capacity Average 20 kgs per feed Burning Rate Average 10 kgs per hour Burning Time per Feed 2 hours Voltage 220V Fuel Diesel oil Burner Italy Burner Feed Mode Manual Fuel consumption (Oil) 5.4-12.6 Kgs/Hour […]
Model CA-200 Picture Burning Rate Average 100 kgs/hour Primary Combustion Chamber 2000 Liters Secondary Combustion Chimney Yes Feed Mode Manual Voltage 220V Power 3.0 Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) Average 53 kg/hour Internal Dimensions 230 x 100 x 90cm (primary chamber) External Dimensions 290 x 200 x 170cm […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://oeoes.com/waste/ Email: [email protected]: [email protected] Nanjing Clover Medical Technology Co.,Ltd. HICLOVER Incinerator/Parts Range Main Feature Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion Chambers Single Combustion Chamber Small, Cheap,10-20kgs/Hr. Three Combustion Chambers(Optional) 3 Chambers for high risk waste Pet Cremation Equipment For Pet(small/big) Cremation Business Animal Incineration Equipment For other animal incineration Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC) Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour Control Mode PLC Auto. PLC Auto. […]
Items/Model HICLOVER TS150(PLC) (Mobile Type) N1155 Picture mobile incinerator Principle Waste Incineration Treatment,trash incinerator Burn Rate Average 150 kg/hour Feed Capacity Average 150kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes(Dry Scrubber) Feed Mode Manual Voltage 220V Power 0.9Kw Oil Consumption (kg/hour) average 20.4 Gas Consumption (m3/hour) […]
Needle Incinerator(Needle & Syringe Destroyers) and Micro Incinerator for COVID 19 waste. HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: http://oeoes.com/waste/ Email: [email protected]: [email protected] Nanjing Clover Medical Technology Co.,Ltd. 2020-07-21
Animal Crematory Incinerator Capacity: Average 80kgs per feeding Item Specification Model A900 Internal Dimensions 120 x 90 x 85 CM Suit for Animal Cat – yes Dog – yes Pig – small Cow – no Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:5.0Meters *(upgrade to […]
Items/Model TS500(PLC) Picture Principle Waste Incineration Treatment Burn Rate 150-200 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2700L Internal Dimensions 190x120x120cm Secondary Chamber 1300L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Oil Consumption (kg/hour) Average 28 Gas Consumption (m3/hour) *** Temperature Monitor Digital Display Temperature Protection Yes Oil Tank 1400L Feed […]
What is called incineration? Incineration is a waste treatment process that involves the combustion of substances contained in waste materials. Industrial plants for waste incineration are commonly referred to as waste-to-energy facilities. … Incineration of waste materials converts the waste into ash, flue gas and heat. What is incineration waste management? In its most basic form, it is the destruction of something, especially waste material, by burning. Incineration is a thermo-decomposition process where the components present in the waste stream are ionized into harmless elements at a higher temperature in the presence of oxygen. What type of waste is incinerated? In incineration applications, the fuel is predominately waste (although fossil fuels may be co-fired) and the oxygen source is air. Combustion produces many of the same stable end products, whether the material burned is natural gas, coal, wood, gasoline, municipal solid waste, hazardous waste, or medical waste. Which is an example of incineration? For example, hospitals and research facilities generally use incinerators to dispose of biological tissues, blood-contaminated materials, and other medical wastes such as disposable hypodermic needles and tubing. Are incinerators safe? What’s more, incinerators release more toxic pollution than coal-fired power plants per unit of energy. To make the same amount of energy as a coal power plant, waste incinerators release: 28 times as much dioxin (a known carcinogen); 5 times as much carbon monoxide (a poisonous gas known as the “silent killer”); Nanjing Clover Medical Technology Co.,Ltd. Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) Burn Rate (Average) 10-20 kg/hour 20-30 kg/hour 30-50 kg/hour 50-100 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://oeoes.com/waste/ Email: [email protected]: [email protected] Nanjing Clover Medical Technology Co.,Ltd. Incinerator Model TS10 PLC, Overview This model Construction is dual/double combustion chamber with 02 units oil burner, batch load incineration equipment. Waste feed chamber is 100Liters (0.1m3, TS10 PLC). Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation. Items/Model TS10(PLC) Picture Burn Rate Average 10 kg/hour Feed Capacity Average 20kg/feeding Control Mode Programmable Logic Controller(PLC) Panel Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed Mode Manual Voltage […]
HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including […]
Items/Model TS300(PLC) Principle Waste Incineration Treatment Burn Rate Average 250 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2000L Internal Dimensions 170x120x100cm Secondary Chamber 1000L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 2.5Kw Oil Consumption (kg/hour) Average 28(DO) Gas Consumption (m3/hour) *** Temperature Monitor Digital Display Temperature Protection Yes Oil Tank […]
Model HICLOVER YD-30C Picture Feed Capacity Average 30-50 kgs per feed Burning Rate Average 30 kgs per hour Voltage 220V Power 0.59Kw Fuel Natural Gas or Diesel oil Burner Italy Burner Feed Mode Manual Fuel consumption (Oil) 10.2-20.0 Kgs/Hour Fuel consumption (Gas) 12.2-24.0m3/Hour External Dimensions 170 x 140 x 190cm (mainbody) Internal Dimensions […]
we supply brand new incinerator for animal waste incinerator for farm,pig,chicken, Agriculture, farms, pigs, cattle, sheep, chickens, ducks,etc small capacity and large set incinerator, with heavy duty combustion chamber, top brand temperature probe with ling lifetime. the fuel type is diesel oil or natural gas or lpg. all incinerator passed ISO9001 and CE Marked. […]
Medium Unit – to handle an average waste production of 500 kg/day.Minimum load capacity: 600 kg.Maximum load capacity: 1,000 kg.Nominal burning rate: 55-80 kg/hr (= 440 C 640kg range per 8hour day). Items/Model TS50(PLC) Picture Principle Waste Incineration Treatment Burn Rate Average 50-100 kg/hour Feed Capacity Average 200-300 kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Optional Upgrade Containerized Mobile Type Incinerator ISO 20′ Full Container Combustion Chamber 560L Internal Dimensions 1000x800x700mm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode Manual Voltage 210/240V 50Hz 1P […]
biohazard waste disposal guidelines 1. The ground should be flat when install the incinerator. There should be 100cm at least between the incinerator and the walls on the two sides and the back, which is in convenient maintenance and repair. 2. A), Place the incinerator main body(combustion chamber) and fixed with bolts and Asbestos tape. B), Place the wet scrubber system and fixed with bolts and Asbestos tape. C). Install chimneys and fixed with bolts, Asbestos tape and Steel Rope. D). Fix the incineration house roof. E). Fix burner, blower, wind tube, electric system, fuel system. 3. Check the electric wire: the incinerator’s electric circuit should be linked with the ground wire to guard against current leakage. The link-up of the electric wire should be checked carefully before starting the incinerator, in case of wrong link-up or leakage. 4. Check of the fuel supply system: Except the Burner’s soft pipe which is used for the fuel flowing-in and flowing-back, all the rest pipes must use brass or steel pipe. No leakage is allowed at pipe junctions. Any leakage should be blocked in time. 5. Install steel rope with the chimney, to avoid tilt by wind. 6. Install net cover at the blower, to avoid sundries. 7. If the fuel is Natural Gas with gas burner, please contact with local administration section and install gas supplier system. 8. Crane or forklift is necessary when download/upload/install incinerator. 9. Topped work house roof after installation. 10.Get the video material: http://www.eclover.net/category/incinerator-video/ Nanjing Clover Medical Technology Co.,Ltd. incinerate china orders incinerators hospital waste disposal ppt safe waste incinerator company medical sharps disposal services in kenya Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) Burn Rate (Average) 10-20 kg/hour 20-30 kg/hour 30-50 kg/hour 50-100 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. […]
We finish this project in year 2010 to 2011 and delivery to Hochiminh port, Vietnam with 1×40’feet open top full container. Items/Model YD-500 Burning Rate (kgs/Hour) 500 kgs/Hr. Feed Capacity (kgs) 800 kgs Equipment Weight 13000 kgs Primary Chamber (Liters) 4000 Secondary Chamber (Liters) 1500 External Dimensions (cm) 320x220x460 Internal Dimensions (cm) 257x147x108 Oil Tank(Liters) […]
Pre-assembled, containerized type Incinerator Model CA100 Picture Waste Treatment Medical Waste Incineration Treatment Feed Capacity Average 100-200 kgs per feed Burning Rate Average 100-120 kgs per hour Burning Time per Feed Average 1-2 hour Control Mode PLC(Programmable Logic Controller Incinerator) Voltage 220V Power 1.0Kw Fuel Diesel oil Burner Italy Burner Feed Mode Manual Temperature Monitor […]
What is the main advantage of incineration? Incineration plays a vital role in making waste management easier and more efficient. Incineration can burn up to 90% of the total waste generated and sometimes even more. However, landfills only allow organic decomposition without making much difference, and non-organic waste keeps accumulating. What materials can be incinerated? A material commonly associated with waste incineration is municipal solid waste (MSW). This type of waste is typically general waste such as household waste, food waste, cardboard, and paper. All of these are safe to incinerate. What are the types of waste? There are 5 types of waste, do you know them all? Liquid Waste. Liquid waste is commonly found both in households as well as in industries. … Solid Rubbish. Solid rubbish can include a variety of items found in your household along with commercial and industrial locations. … Organic Waste. … Recyclable Rubbish. … Hazardous Waste. Which waste is highly infectious? Infectious waste: waste contaminated with blood and other bodily fluids (e.g. from discarded diagnostic samples), cultures and stocks of infectious agents from laboratory work (e.g. waste from autopsies and infected animals from laboratories), or waste from patients with infections (e.g. swabs, bandages and disposable waste management disposal pit latrine incinerators and rubbish pit electrial incnirator for hospital waste incinerators for corpse incenerators for sale inciratorमीन्स इन हिंदी waste incinerator incineration cost quantities what is incineration of waste safety waste incinerator Nanjing Clover Medical Technology Co.,Ltd. Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) Burn Rate (Average) 10-20 kg/hour 20-30 kg/hour 30-50 kg/hour 50-100 kg/hour Control […]
Item Specification Model YD-20C Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy oil burner: 02 sets Oil Tank: 100Liters Optional: Mobile Trailer for Incinerator Phone: +86-13813931455(whatsapp/wechat)Website: http://oeoes.com/waste/ Email: [email protected]: [email protected] Nanjing Clover Medical Technology Co.,Ltd. bio medical waste management ppt 2020 HICLOVER Incinerator/Parts Range Main Feature Medical […]
Mobile Containerized Waste Incinerators pets or human cremation emergency use Model CA-200 Picture Burning Rate Average 100 kgs/hour Primary Combustion Chamber 2000 Liters Secondary Combustion Chimney Yes Feed Mode Manual Voltage 220V Power 3.0 Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) Average 53 kg/hour Internal Dimensions 200 x 100 x […]
Waste is thermally decomposed in the primary chamber at temperatures of 800 °C +. The resulting gaseous products are completely oxidized in the secondary chamber at higher temperatures with sufficient resident time. Other specifications are as follows. A combustion chamber of waste: * Perfectly tight door for the manual loading of waste. The loading should be […]
Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production Shipping Volume Shipping Weight Delivery Location TS30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks 5 m3 3000 kgs Shanghai Port TS50 average 50kgs per hour Average 250 SickBed Diesel Oil 1 set […]
Medical Waste Incinerator Capacity: average 50-100 kgs per hour Items/Model TS50(PLC) Picture Principle Medical Waste Incineration Burn Rate Average 50-100 kg/hour Feed Capacity Average 100kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) average 16.9 Gas […]
medical waste incinerator iraq price HICLOVER TS10 PLC 10kgs per hour Items/Model TS10(PLC) Picture Burn Rate Average 10 kg/hour Feed Capacity Average 20kg/feeding Control Mode Programmable Logic Controller(PLC) Panel Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.5Kw Oil Consumption (kg/hour) average 8.4kg/hour Gas […]
Items/Model CA100 Picture Principle Medical Waste Incineration Treatment Burn Rate Average 100 kg/hour Feed Capacity Average 200kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 1.3 Kw Oil Consumption (kg/hour) Average 20.4 Kgs/Hour Gas Consumption (m3/hour) *** Temperature […]
HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like […]
Incinerator Model A1500, Overview This model is big-scale animal cremation equipment for big animals. Construction is dual/double combustion chamber with 03 units oil/gas burner, batch load incineration equipment. Animal feed chamber is 1500Liters (Model: A1500). Primary & Secondary combustion chambers and included mix-combustion chamber, smoke filter chamber with firebrick and Refractory Concrete chamber. Batch load […]
you have to do custom clearance your side. and shipping document with bill of lading, invoice, packing list only. we have incinerator in PK and AFG but iam not sure where it is. all incinerator passed EU CE and ISO. if natural gas or LPG fuel, you have to contact with local gas supplier to […]
Vertical closed furnace combustion chamber incinerator Medical waste, disposable syringes, infusion sets processing, cotton yarn, the operating room, the residual limb, waste rubber gloves, protective clothing and infectious and harm venereal hospital bed supplies, general wastes. 10-20kg/time (daily burn 3-6times, each time consume about 1 hour) total daily waste capacity 120 kg Incinerator Items/Model HICLOVER TS10(PLC) Burn Rate (Average) 10-20 kg/hour Feed Capacity(Average) 20kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V 2P Power 0.5Kw Burner Type Italy Brand Oil Consumption (kg/hour) […]
30kgs per hour(average) medical waste incinerator, design dual combustion chambers(primary chamber and secondary chamber), smoke filter chamber, PLC auto. control system, 0.33m3(330liters) primary combustion chamber, italy oil or gas fuel burner. for small hospital medical waste treatment. Buy waste incinerator, find hiclover Items/Model TS30 PLC Principle Waste Incineration Burn Rate Average 30kgs/hour Fuel Type Diesel Oil/Natural […]
BURNING RATE : -100-150kgs per hour MINIMUM OPERATING TEMPERATURE : 800-1000 oC ( PRIMARY COMBUSTION ) MAX OPERATING TEMPERATURE : 1000-1200 oC ( AFTER BURNER COMBUSTION ) SECONDARY BURNING CAPACITY : COMPULSORY DENSITY INSULATION : 50 mm high Refractory capacity : min 114mm HEAVY DUTY REFRACTING LINING TO WITHSATND 17500C AVEARGE BURN OUT TIME : […]
Advantages of Waste Incineration Decreases Quantity of Waste. … Efficient Waste Management. … Production of Heat and Power. … Reduction of Pollution. … Incinerators Have Filters For Trapping Pollutants. … Saves on Transportation of Waste. … Provides Better Control Over Odor […]
HICLOVER – Containerized Mobile Incinerator Medical Waste Incinerator Model CA50 Model CA50 Picture Waste Treatment Medical Waste Incineration Treatment Feed Capacity Average 100 kgs per feeding Burning Rate Average 50 kgs per hour Burning Time per Feed Average 2 hour Control Mode PLC(Programmable Logic Controller Incinerator) Voltage 220V Power 1.0 Kw Fuel Diesel oil Burner Italy […]
Light Weight Small-Scale Medical, Mobile Optional Type Model YD-30 Picture Burning Rate average 30 kgs/hour Feed Capacity average 40 kgs Paimary Combustion Chamber 200 Liters Secondary Combustion Chamber 100 Liters Mix Combustion Chamber Yes Feed Mode Manual Voltage 220V Power 0.59Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) average 13.3 […]
there was one set oil fired incinerator send to Kenya. average capacity 30-50kgs per hour for small hospital. if you have any requirement, please send technical details such as capacity(kgs/hour or day), diesel oil or natural gas, etc, we will support for best incinerator and price. Mobile: +86-138139 31455(WhatsApp) Nanjing Clover Medical […]
HICLOVER Top Feeding Door Waste Incinerators ▲▲▲Large Feeding Door ▲▲▲Better for Animal Waste Cremation ▲▲▲HICLOVER Brand Section ***Primary Combustion Chamber ***Secondary Combustion Chamber ***Smoke Filter Chamber ***Optional Wet Scrubber System(1 section or 3 sections) Phone: +86-13813931455(whatsapp/wechat)Website: http://oeoes.com/waste/ Email: [email protected]: [email protected] Nanjing Clover Medical Technology Co.,Ltd. Items Side Loading Door Top Loading Door Cost Cheap High cost Manufacture Tech. Easy A litter difficult […]
Items/Model TS1000 Picture Principle Solid Waste Incineration Treatment Burn Rate Average 1000kg/hour Feed Capacity Average 6000kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 4800Liter Internal Dimensions 400*120*100 cm Secondary Chamber 1000Liter Feed Mode Manual/Forklift Voltage 220V/380V Power 8.0Kw Oil Consumption (kg/hour) Average 67(DO) Gas Consumption (m3/hour) *** Temperature Monitor Digital Display Temperature Protection Yes […]
MEDIUM-CAPACITY ANIMAL CARCASS INCINERATOR HICLOVER Model TS100(PLC) with wet scrubber optional Items/Model TS100(PLC) Picture Principle Waste Incineration Treatment(Poultry and dead fish Incinerator Machine) Burn Rate Average 50-100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 970L Internal Dimensions 120x90x90cm Secondary Chamber 480L Smoke Filter Chamber Yes(Dry Scrubber) Feed Mode Manual Voltage 220V-240V Power 0.7Kw […]
Medical Waste Incinerator for Coronavirus Disease( COVID-19). * Full variety incinerator with Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator. * Single burning chamber, double combustion chambers, three combustion chambers and also multi-combustion chambers waste incinerators. * System solutions for clinical waste environmental. * High […]
How medical waste is incinerated? The pyrolytic incinerator comprises a pyrolytic chamber and a post-combustion chamber. Medical waste is thermally decomposed in the pyrolytic chamber through an oxygen-deficient, medium-temperature combustion process (800– 900°C), producing solid ashes and gases. What are the treatment methods for treatment of bio medical waste? Thermal processes Low-heat systems (operates between 93 -177oC) use steam, hot water, or electromagnetic radiation to heat and decontaminate the waste High-heat systems employ combustion and high temperature plasma to decontaminate and destroy the waste. … Incineration. Autoclaving. Microwaving. Deep Burial. Nanjing Clover Medical Technology Co.,Ltd. waste to energy plant suppliers medical waste incinerator types hospital waste disposal methods ovens incineration sale medical waste incinerators in south africa where and how incinerator install Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) Burn Rate (Average) 10-20 kg/hour 20-30 kg/hour 30-50 kg/hour 50-100 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. Combustion Chamber 100L 210L 330L […]
TS10 PLC Waste Incinerator Outline Dimension:1.75 x 1.3 x 1.7m Weight: Ave.1500kgs Main body(Primary combustion chamber) Material:Carbon Steel Q235B+Stainless Steel 310s+refractory firebrick material(high temperature resistance up to 1750℃) Capacity: 10-20kg/batch Combustion temperature: 800-1000℃ With chamber door, oxygen supplementation wind port, burner port, temperature control and alarm device, etc. [1 unit ] Secondary combustion chamber Material:Carbon Steel Q235B+Stainless Steel 310s+refractory firebrick material(high temperature resistance up to 1750℃) Combustion temperature:1000-1200℃ With observation port, burner port, temperature control and alarm device, etc. [1 unit ] High temperature flue gas filtration chamber Material: Outside plate: Q235B, Inside acid-resisting, alkali-resisting refractory poured material. With ash door and filtration material. [1 unit ] 1# BURNER OF 1# CHAMBER Riello brand (Italy) (High quality, combustion-resisting) Fuel: Natural gas [1 unit ] 2# BURNER OF 2# CHAMBER Riello brand (Italy) (High quality, combustion-resisting) Fuel: Natural gas [1 unit ] Chimney Material: Stainless steel,304 Length: 5m ( other length as customer request) [1 unit ] Temperature control device -Thermocouple [2 unit ] Control valve [2 pcs ] Fastening and sealing elements -Bolts, nuts, washers, paper packing etc. [1 set ] Control Cabinet Rain proof type Power indicator Voltage: 220V Temperature indicator Overload protector Leakage protection device [1 set ] Nanjing Clover Medical Technology Co.,Ltd. Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour Control Mode PLC Auto. PLC Auto. PLC […]
Incinerators must be able to support different power sources (PV solar system , diesel Electric generator , local or compound mini-scale grid).Each unit shall include a complete vertical exhaust and stack system, including the following features: • Steel construction. Packing Details Serie No. Part Name Size(M) Weight(Kgs) 01 Incinerator Mainbody 1.8 x 1.2 x 1.7(LxWxH) […]
What are the objectives of incineration? Incineration plants produce heat and power from waste, reduce waste disposal to landfills, and discharge harmful emissions and bottom ash. The objective of the incineration plant is to maximize desirable outputs (heat and power) and minimize undesirable outputs (emissions and bottom ash). What is incinerators used in hospitals? Medical incinerators are designed safely to dispose of harmful materials at high temperatures. The process ensures no harmful gases are released into the environment. Medical waste incinerators have scrubbers to clean the polluted gases and other particulate matter. Which is better landfill or incineration? Its director Jacob Hayler told us: “It is better to recover energy from non-recyclable waste through (incineration), than send it to landfill.” … Mr Hayler says that overall greenhouse gas emissions from incineration are lower than from landfill. How does incineration affect our environment? Pollutants emitted by incinerators that appear to have the potential to cause the largest health effects are particulate matter, lead, mercury, and dioxins and furans. However, there is wide variation in the contributions that incinerators can make to environmental concentrations of those contaminants. Nanjing Clover Medical Technology Co.,Ltd. temperature required for body parts incineration incinerator for clinical methods of waste management haat incinerator india contact number for hazardous waste management companies in kumasi https www pvc org en p pvc incineration dioxins disposal of clinical waste Suitably designed pollution control devices such as scrubbers, filters or electrostatic precipitators, shall be installed/retrofitted with the incinerator to achieve emission limits.” “Each unit shall include a complete vertical exhaust and stack system, including the following features: • Steel construction. • Refractory lining in the lower section. • The exit height of the stack shall be not less than a range of 3-12 metres above ground level depending on the capacity of the incinerator unit. • The diameter of the stack shall be selected by the Contractor to deliver an exhaust exit velocity of not less than 10 metres per second vertically upwards when at full scale operation. • An emission stack sampling port shall be included immediately above the secondary chamber. Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) Burn Rate (Average) 10-20 kg/hour 20-30 kg/hour 30-50 kg/hour […]
Primary chamber:Heavy duty mild steel casing, High quality Refractory lining and insulation 01 x natural gas ignition burners (automatic) 01 x temperature sensor points with complete internal fans.Secondary Chamber:Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas burners (automatic) with complete 01 internal fans. 02 Sec gas residence times.Third Chamber:Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas ignition burners (automatic) with complete internal fans. 02 Sec gas residence time.Integrated dual flu gas washer: Resultant gasses passed through dual gas filtration system for maximum clean emission. It is also equipped with chain filters.Chimney:Heavy duty 5mm or more stainless steel casing mild steel casing.Stack cap/spark arrestors.Control Panel:a.Temperature Monitoring with 4 digit display.b.Thermostat control device for burner (fuel saver)c.Temperature control 0-12 hours.d.Integral fan timer control
incinerator for poultry farm dead checkin 575 kg, HICLOVER YD50 incinerator or TS50 Model YD-50 Picture Burning Rate Average 50 kgs/hour Feed Capacity Average 150 kgs/feeding Primary Combustion Chamber 700 Liters Secondary Combustion Chamber 300 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.8Kw Fuel Type Diesel Oil/ Natural Gas/LPG Burner Italy Original […]
Medical waste is currently managed via an old medical waste incinerator; which also manages the associated medical waste delivery and ash removal arrangements.Pathological waste: organs, tissues, surgical specimens, bodily fluids removed during surgery or autopsy. Mix and moisture content not known.Allow for weekly deliveries @ 8 hour per day operation = 11 kg per hour […]
we supply medical two chambers incinerator 800 to 1200 degrees. the capacity from 10kgs per hour to moran than 1000kgs per hour. all incinerator pass ISO and CE certificate. HICLOVER brand incinerator made in chin and use heavy duty refractory firebrick, fix with PLC AUTO control system. Call on Mobile: +86-138139 31455(WhatsApp) Nanjing Clover Medical Technology Co.,Ltd. Items/Model TS10(PLC) TS20(PLC) TS30(PLC) […]