Dual heat burners and dual chamber incinerator Burning capacity up to 30 Kg per hour Main Product List Primary Combustion Chamber(Main body stainless steel) Secondary Combustion Chamber(Main body stainless steel) Mix-Combustion Chamber Wet Scrubber( Washing Tower)(Main body stainless steel) Incinerator Control Case Chimney:5.0Meters Stainless Steel Italy gas burner: 02 sets Oil Tank (if oil fuel): […]
diesel powered incinerator means the burner type is light oil with diesel oil fuel. the incinerator made by us have 2 combustion chamber, the primary with 1-2 burners, and the secondary chamber with 1 burner. all incinerator fixed with PLC Auto control system. Nanjing Clover Medical Technology Co.,Ltd. Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) […]
HICLOVER incinerator exert the advantages and discard the disadvantages of the same kind of equipment at domestic and abroad. It is an unique and international advanced medical waste incineration equipment. The equipment is small size, high efficiency, reasonable process, leading technologies and a high harmless degree, ideal garbage treatment equipment for hospital, laboratory, hotel, station, etc. […]
It features unique and advanced merits with compact size, high burning effect, reasonable burning technology, high degree of non-harm etc.It is an ideal choice for waste treatment of hospitals, hotels and various areas. Features: (1) Gasifiedpyrolysis incineration is used for burning many kinds of waste.(2) Waste can be burned once everyday by gasified incineration.(3) Gasified incineration, mixed incineration and burnout treatment ensures low emission standard of dust,dioxin etc.(4) Totally enclosed operation is suitable for treating infectious waste to avoid secondary pollution. (5) Compact structure and small land occupation. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: oeoes.com/waste Email: [email protected]: [email protected] Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L 1200L […]
Incinerator Model TS250 PLC, Overview This model is small-scale waste incineration equipment for small waste output. Construction is dual/double combustion chamber with 02 units oil burner, batch load incineration equipment. Waste feed chamber is 1800Liters (1.8m3, TS250 PLC). Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the bottom of chamber. Incinerator […]
Waste Incinerator Door: Side/Front Opening Door VS. Top Opening Door Items Side Loading Door Top Loading Door Reference Cost Cheap High cost Manufacture Tech. Easy A litter difficult Safty safe safer Incinerator Shape L/ I L Loading manual big door can be by Forklift Land occupation small big Ash door same with feeding door or […]
Waste Incineration Treatment Diesel Oil type Model TS150 Main Parts List as below: Primary combustion chamber Secondary combustion chamber smoke filter chamber incinerator PLC control case chimney, 10meters, stainless steel Italy Oil fule burner oil tank 300liters with full spare parts: oil burner, air blower, temperature thermocouple
Curing Duration,need a small incinerator, they discard 100 liters of covid masks daily.batch load, direct fire, mobile incinerator for a variety of applications including medical waste. The unit is one of the lightest in its class , facilitating deployment for virus outbreaks and disaster relief operations. Primarily running on diesel 1. Where can I watch a video of a real-life application? 2. The modulating under air burners ensure consistent high temperatures needed to destroy infectious waste, whilst retaining the flue gas for sterilization. Simply load waste into the chamber, close the door and turn on the unit. 3. When approved and paid for, how many days for shipment? 4. As per the requirement we have ordered an Incinerator that can process 100kg hospital waste and as per the end user they are only able to put 3 bags of waste which are approximately 10kg each. So we are only able to process 30 Kg of waste instead of 100Kg. As per the hospital the chamber volume is very small and can not process 100kg hospital waste 5. Can you give me the listing of extras needed, and installation of the TS150 PLC Incinerator and am in need of technical assistance? 6. What are the most commonly needed repair parts?a) Waste Auto Loading Ram Hopper b) Standard Tools (What the tools are there?, Please figure out) c) Recommended spare parts (1 year) (such as burner, refactor cement, temperature probe, etc.) d) Commissioning and Training e) Support wires, clamp and bracket as chimney is 33 m height HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification. Auto. Control Waste Incinerator & Auto. Roll Air Filter(Air Purification) Waste Incinerator RFQ(Request for Quotation) http://oeoes.com/waste/ad/rfq/ EStore for Waste Incinerators http://www.haiwos.com 2022-06-24 […]
Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production Shipping Volume Shipping Weight Delivery Location TS30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks 5 m3 3000 kgs Shanghai Port TS50 average 50kgs per hour Average 250 SickBed Diesel Oil 1 set […]
Double Combustion Chamber Medical Waste Incinerator Hot Face,High aluminum firebrick 55% of Al203,1750°C Grade. Code face, High Rate Refractory Ceramic Fiber, 1050°C Grade
Large Capacity Animal Pet Cremation HICLOVER Model A1500 with E-Power Auto. Door Model A1500 Internal Dimensions 150 x 100 x 96cm Suit for Animal Cat – yes Dog – yes Pig – small Cow – small Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:10.0Meters *(upgrade to […]
Is medical waste an incinerator? What is Medical Waste Incineration? Medical waste incineration is the process of burning specific wastes, including pathological, trace chemotherapy and non-hazardous pharmaceutical wastes as it is considered the safest, most effective means of treatment and prevents harm to the environment and our health in general. How medical waste is incinerated? The pyrolytic incinerator comprises a pyrolytic chamber and a post-combustion chamber. Medical waste is thermally decomposed in the pyrolytic chamber through an oxygen-deficient, medium-temperature combustion process (800– 900°C), producing solid ashes and gases. What is incinerators used in hospitals? Medical incinerators are designed safely to dispose of harmful materials at high temperatures. The process ensures no harmful gases are released into the environment. Medical waste incinerators have scrubbers to clean the polluted gases and other particulate matter. Can biomedical waste be incinerated? As stated by Health Care Without Harm, non-incineration treatment technologies are a growing and developing field. Most medical waste is incinerated, a practice that is short-lived because of environmental considerations. The burning of solid and regulated medical waste generated by health care creates many problems. What are the types of incinerator? The following are types of incinerators: ROTARY KILN. FLUIDIZED BED. LIQUID INJECTION. MULTIPLE HEARTH. CATALYTIC COMBUSTION. WASTE-GAS FLARE. DIRECT-FLAME. Which biomedical waste is incinerated? The 4 categories that medical waste falls under are General, Infectious, Hazardous and Radioactive. Biomedical waste is incinerated in either a hospital incinerator or through industry standard biomedical waste incinerators. Nanjing Clover Medical Technology Co.,Ltd. Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) Burn Rate (Average) 10-20 kg/hour 20-30 kg/hour 30-50 kg/hour 50-100 kg/hour Control Mode PLC Auto. PLC Auto. […]
平面口罩机参数: Semi-Automatic Mask Machine l Power supply: 3.3KW mono phase l Mask Size: 175mm*80-100mm (two or three layers) l Nonwoven (GMS): 10-50g l Capacity: 120 to 150pcs/min l Dimension(L*W*H):3800mm*500mm*1400mm l Net Weight: about 1000kg 焊接机参数: Welding Machine l Capacity: 5 to 10pcs/min l Power supply: 8.5KW mono phase l Compressed Air connection: 0.5 to 0.7Mpa l Dimension(L*W*H): 900mm*650mm*1380mm l Net weight: approx. 50kg KN95口罩机参数: N95 Mask Machine l Capacity: […]
Key Features: — Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator. — Single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators. — System solutions for medical waste environmental. — […]
Waste Disposal Methods in Hospital • An 8 hour daily operating cycle of ash removal, pre-heat and burn with continuous loading if required. The automated burn completion and cool down cycle will take place overnight. • The incinerators shall be capable of using diesel fuel as a supplemental fuel while the associated management equipment shall […]
Heavy duty firebrick for incinerator chamber 55% of Al203 65% of Al203 75% of Al203 Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: oeoes.com/waste Email: [email protected]: [email protected] Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. Combustion Chamber 100L 210L 330L 560L Internal Dimensions 50x50x40cm 65x65x50cm […]
Medical Waste Incinerators in Stock. Twitter: https://twitter.com/hiclovercom Phone/WhatsApp/Wechat: +8613813931455, Web: oeoes.com/waste Web: www.clover-incinerator.com Double Combustion Chamber,Double Italy Burner,Smoke Filter Included,Burning Rate: 50-200kgs per hour optional,Primary Combustion Chamber: 1.57M3(1570Liters),Incinerator Mainbody steel: 8mm thickness,Paint for outside face: 800°C Rate,Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate,Idea for campsite average or below 600 people,Chimney: 10 Meters, Stainless […]
Waste Incineration HICLOVER Model TS75 Items/Model TS75(PLC) Picture Principle Waste Incineration Burn Rate Average 75 kg/hour Feed Capacity Average 150kg Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 770L Internal Dimensions 100x81x95cm Secondary Chamber 385L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) Average 16.9 Gas Consumption (m3/hour) *** […]
There are generally 4 different kinds of medical waste: infectious, hazardous, radioactive, and general.For the purposes of this review these sources are defined as giving rise to four major categories of waste: municipal solid waste, industrial waste, agricultural waste and hazardous waste. What Colour bags are used for clinical waste? Clinical waste. Correct segregation. Colour […]
News from: https://www.thestar.com.my/news/nation/2020/01/26/wuhan-virus-china-mobilises-medical-teams-to-fight-new-coronavirus WUHAN (Bernama): China is mobilising medical staff to aid Wuhan, the centre of the novel coronavirus (2019-nCoV) outbreak, as the country reported 830 confirmed cases of pneumonia, caused by the virus and 25 deaths by the end of Thursday (Jan 23). By Thursday midnight, Hubei Province in central China reported 549 cumulative confirmed […]
Items/Model TS50M Picture Burn Rate Average 50 kg/hour Feed Capacity Average 50-150 per feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 450L Internal Dimensions 75x75x80cm Secondary Chamber 225L Smoke Filter Chamber Yes Feed Mode Manual Feeding Voltage 220V Power 0.5Kw Oil Consumption (kg/hour) Average 13.3 Gas Consumption (N.G, m3n/Hour) Average 16 Gas Consumption […]
https://www.haiwos.com/#!/Model-TS10-Incinerator-with-wet-scrubber-Spray-Tower-and-Defogging-Tower/p/472484002/category=0 Incinerator Items/Model HICLOVER TS10(PLC) Burn Rate (Average) 10-20 kg/hour Feed Capacity(Average) 20kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 3.0Kw Burner Type Italy Brand Oil Consumption (kg/hour) 6 N.Gas Consumption (m3n/hour) *** Temperature Monitor Yes Temperature Thermometer […]
1. N95 and Disposable Mask Machine 2. 400mm and 1600mm Melt blown Production Line 3. ES Fiber Production Line N95 Face Mask Machine Production Line Melt blown Production Line A.)Optional Capacity: 1600mm Efficiency: 95-97% FOB Term Price: USD per set Price Valid: 5days. Ave.60 Days ready for shipping. In stock […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://oeoes.com/waste/ Email: [email protected]: [email protected] Nanjing Clover Medical Technology Co.,Ltd. HICLOVER is now offering a full range of medical waste incinerators, designed to provide efficient waste destruction, utilizing best available technologies and environmentally friendly process. Due to the secondary chamber with its 2 second retention period, our medical incinerator range is well suited to process medical waste. Our products ensure […]
Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production Shipping Volume Shipping Weight Delivery Location TS30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks 5 m3 3000 kgs Shanghai Port TS50 average 50kgs per hour Average 250 SickBed Diesel Oil 1 set […]
Incinerator burn medical and bio waste Items/Model TS100(PLC) Picture Principle Medical Waste Incineration Treatment Burn Rate Average 100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes(Dry Scrubber) Feed Mode Manual Voltage 220V/380V Power 0.7Kw Oil Consumption (kg/hour) average 20.4 Gas Consumption (m3/hour) *** […]
Incinerator Parts Mineral Insulated Thermo couple sensor K-Type 300SS K type 300SS: M27*2, 300mm Ins,2520 S.S, 2.5mm core HICLOVER – Medical Environmental WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet Animal Cremation Solid Waste Incinerator Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: oeoes.com/waste Email: [email protected]: [email protected] Nanjing Clover Medical Technology Co.,Ltd. 2020-06-27
30kgs rate 60kgs feed oil and gas burner small waste incinerator for Afghanistan Machine Working mode Oil or Gas + Power Voltage 220V Oil consumption (lit/hour) Average 13.3lit/hour/chamber Gas consumption (NG) (m3/hour) 16.0 (m3/hour) (NG) Gas consumption (LPG) (m3/hour) 11.7 (m3/hour) (LPG) Burning rate Average 30kg/hour Feed mode Manual Primary Combustion chamber 360 Liters Secondary Combustion […]
N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set l Dimension(L*W*H): 1037*855*1780 l Power Supply 15.3kw mono phase l Net Weight: approx.: 1500kg HICLOVER – Medical Environmental WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet Animal Cremation Solid Waste Incinerator Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: oeoes.com/waste Email: [email protected]: [email protected] Nanjing Clover Medical Technology Co.,Ltd. […]
Small Waste Incinerator, 10kgs per hour capacity, PLC control Items/Model TS10(PLC) Picture Burn Rate Average 10 kg/hour Feed Capacity Average 20kg/feeding Control Mode Programmable Logic Controller(PLC) Panel Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.5Kw Oil Consumption (kg/hour) average 8.4kg/hour Gas Consumption (m3/hour) average […]
Model A1500 Picture Brand/Product Code HICLOVER/N1134 Burning Rate Average 50 kgs/hour Feed Capacity Average 150 kgs/feeding Primary Combustion Chamber 1500 Liters Secondary Combustion Chamber 500 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V/380V Fuel Type Diesel Oil/ Natural Gas/LPG Burner Italy Original Oil Consumption (Diesel Oil) Average 34 kg/hour […]
Medical waste is posing a growing problem all over the world, jeopardizing the health of staff, patients, disposal workers and anyone else coming into contact with the often hazardous materials discarded by hospitals and other healthcare sites. Hospital waste varies from site to site and the biggest challenge is to dispose of this wide range of waste streams. Incineration is still the preferred way to process medical waste without endangering the heath patients, staff or anyone else coming into contact with them. Clinical waste is costing more and more to dispose of safely. Health Clinics and Health center can now handle their own waste streams using one of our specialist medical incinerators. Destroying hazardous waste at source is by far the most effective and efficient way of handling waste that could potentially spread diseases or viruses. Average 20%-25% of the total waste generated by healthcare establishments is regarded as hazardous and may create a variety of health and environmental risks if not managed and destroyed in an appropriate manner. With years worth of experience in this sector, our medical range of incinerators are designed to cater for the economical needs of small clinics to the more demanding and specialized requirements of large hospitals in their waste management processes.HICLOVER is now offering a full range of medical waste incinerators, designed to provide efficient waste destruction, utilizing best available technologies and environmentally friendly process. Due to the secondary chamber with its 2 second retention period, our medical incinerator range is well suited to process medical waste. Our products ensure efficient, clean and hassle-free disposal of medical waste is possible. The incineration of clinical waste including pathological waste (red bag waste), Biohazards & Sharps, General Medical Waste, from Hospitals, Research Center, Pharmaceutical Companies , Drug Manufactures, Primary Care Trusts, Cosmetic Surgery Clinics, Nursing Homes, Care Homes and other Clinical Waste. ○Middle-Small Capacity(TS Model)※Main Features:— Double Combustion Chamber— Double Italy Burner–Burning Rate: 10-100kgs per hour–Combustion Chamber: 0.1M3-1.2M3※Optional Function/Parts/Material/Burning Rate: — Stainless Steel Chimney — Dry Smoke Filter Chamber— Chimney Height Custom Made— Upgrade/Downgrade Burning Rate ○Large-Middle Capacity(YD Model)※Main Feature:–Three Combustion Chambers— Double Italy Burner–Burning Rate: 30-600kgs per hour–Combustion Chamber: 0.36M3-5.5M3※Optional Function/Parts/Material/Burning Rate: — Stainless Steel Chimney — Dry Smoke Filter Chamber— Chimney Height Custom Made— Semi-Automatic Waste Feeding— 3-Section Wet Scrubber System— Movable Platform Feeding Door— Additional Burner— Upgrade/Downgrade Burning Rate ● Service before and after Installation — Factory training for installation, operational and maintenance with free cost.— Online service support for installation, operational and maintenance with free cost.— Onsite installation, operational and maintenance training— Onsite service support after installation ● Spare parts supportHICLOVER now offers spare parts including:— Burners (diesel oil, LPG or natural gas)— Element for burners— Fire ropes— Incinerator chamber maintenance materials— Air Fan — Temperature element— Smoke filter brick— Control box— Other parts Nanjing Clover Medical Technology Co.,Ltd. Tel: +86-25-8461 0201 Fax: +86-25-8461 0406 Website: oeoes.com/waste Email:[email protected]: [email protected]
Incinerator for Medium type Hospital 100 -200 Kg per day incineration at south of switzerland fabrication incinerateur waste to energy technologies elastec incinerator hospital waste management Incinerator Items/Model TS10(PLC) Burn Rate (Average) 10-20 kg/hour Feed Capacity(Average) 20kg/feeding Control Mode PLC Automatic Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed […]
incinerator manufacturer,medical incinerator,small scale incinerator,oil fired incinerator Items/Model TS100 Burn Rate Average 100 kg/hour Feed Capacity Average 200 kg/feed Control Mode PLC Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) 14–28 Gas Consumption (m3/hour) 10–32.2 Temperature Monitor Yes Temperature Protection […]
Nanjing Clover Medical Technology Co., Ltd. is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical waste, Pet animal cremation and other Solid waste. The capacity from 10kgs/Hr. to 500kgs/Hr., up […]
Double Combustion Chamber,Double Italy Burner,Smoke Filter Included,Burning Rate: 50-200kgs per hour optional,Primary Combustion Chamber: 1.57M3(1570Liters),Incinerator Mainbody steel: 8mm thickness,Paint for outside face: 800°C Rate,Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate,Idea for campsite average or below 600 people,Chimney: 10 Meters, Stainless steel… Items/Model TS150(PLC) Principle Waste Incineration Treatment Burn Rate Average 150 kg/hour *(50/100/200kgs/hour […]
Diesel Biogas Dual Chamber Incinerator, with diesel oil and Biogas burner Incinerator Items/Model HICLOVER TS50 Burn Rate (Average) 50 kg/hour Feed Capacity(Average) 100kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Dual chamber up to 50 kg per hour semi-automatic Independent control of primary and secondary temperatures via control panel 850 -1100 C 1000- 1200 C >= 2 seconds <5% Electronic control panel providing friendly interface for operators with minimal training Mobile: +86-138139 31455(WhatsApp) Website: oeoes.com/waste Email: [email protected] Email: […]
There are 03 sets Model YD-100 delivery to Iraq between year 2013 to 2014. The incinerator use for local several construction sites and all fuel type is diesel oil. Items/Model YD-100 Burning Rate (kgs/Hour) 100 kgs/Hr. Feed Capacity (kgs) 200 kgs Equipment Weight 5300 kgs Primary Chamber (Liters) 1200 Secondary Chamber (Liters) 500 External […]
1. For clinic,lab, small hospital with low waste output capacity, no condition with other medical waste treatment(Underdeveloped country or area, or emergency situations ). 2. Doctor, nurse treat the syringes, needle, infusion set immediately after use, plug to play, no dispersion risk. 3. melting the syringes needle with 1250Celsius high temperature to metal slag, sterilization […]
The Incinerator units shall be designed to last in operation in a tropical environment for a minimum period of 10 years if the specified maintenance schedule is followed. All metal surfaces (except combustion chamber internal fittings) shall be either galvanized, enameled, painted or otherwise treated against atmospheric and process induced corrosion,Medical waste management pdf. The […]
High Temperature Protection Gloves and High Temperature Protection Masks for incinerator operation Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: oeoes.com/waste Email: [email protected]: [email protected] how to incinerate aerosol spray incinerator for sanitary napkins for schools dial thermometer for incinerators mobile incinerator medical waste what are the costs and benefits of building a brick incinerator for hospital drum inceniration Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) […]
Small Medical Waste Incinerator 2 combustion chamber with scrubber for Virus medical waste On-Site Incineration Solution Medical waste incineration involves the burning of wastes produced by hospitals, veterinary facilities, and medical research facilities. These wastes include both infectious (“red bag”) medical wastes as well as non-infectious, general housekeeping wastes. Items/Model TS30(PLC) Picture Burn Rate […]
Model YD-100 Picture Burning Rate 100-150 kgs/hour Primary Combustion Chamber 2000 Liters Secondary Combustion Chamber 500 Liters Feed Mode Manual Voltage 220V/380V Power 2.5Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) Average 28 kg/hour Gas Consumption (Natural Gas) *** Internal Dimensions 180x115x98 cm (primary chamber) External Dimensions 270x185x280cm (without chimney) Temperature […]
Waste Incineration Treatment Burn rate (rate of waste incineration) -at least 50 kg per hour Oil tank smoke filter chamber Items/Model TS100(PLC) Picture Principle Waste Incineration Treatment Burn Rate Average 50-100 kg/hour Feed Capacity Average 200kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1000L Internal Dimensions 120x100x90cm Secondary Chamber 540L Smoke Filter Chamber Optional Feed […]
Items/Model TS75 Picture Principle Solid Waste Incineration Burn Rate Average 75 kg/hour Feed Capacity Average 100kg Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 600L Internal Dimensions 100x60x100cm Secondary Chamber 300L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 3.0Kw Oil Consumption (L/Hour) 15-20 Natural Gas Consumption (m3n/hour) ** Temperature Monitor Digital Display Temperature […]
*Primary combustion chamber *Secondary combustion chamber *Smoke filter chamber * Stainless Steel chimney *Auto PLC control system *Italy brand burner * Automatic Protection Operator(APO) *Heavy duty refractory chamber *Corundum Temperature Thermometer *CE/ISO certification,etc Incinerator Items/Model HICLOVER TS500(PLC) Burn Rate (Average) 500-600 kg/hour Feed Capacity(Average) 600kg/feeding Control Mode PLC Automatic Primary Combustion Chamber […]
Item Specification Model YD-20C Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy oil burner: 02 sets Oil Tank: 100Liters Optional: Mobile Trailer for Incinerator Mobile Type Incinerator Phone: +86-13813931455(whatsapp/wechat)Website: http://oeoes.com/waste/ Email: [email protected]: [email protected] Nanjing Clover Medical Technology Co.,Ltd. HICLOVER Incinerator/Parts Range Main Feature Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion […]
Hiclover supply medical waste incinerators with capacity 10kgs per hour to 500kgs per hour. The incinerator with dual/double combustion chamber and dry filter chamber, two fuel burner from Italy manufactured, hot sale model for small scale waste output, the capacity is 30kgs per hour and 50kgs per hour. We are famous small scale incinerator manufacturer […]
Items/Model TS50(PLC) Picture Principle Medical Waste Incineration Burn Rate 50-100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Gas Flue Washing System incineration of medical waste Feed Mode Manual Voltage 220V Power 4.0 Kw Oil Consumption (kg/hour) average 16.9 Gas Consumption (m3/hour) average 20.2 Temperature Monitor […]
how does the incinerator works? the incinerator mainly for medical waste and animal waste treatment with oil/gas fired in the primary chamber with high temeprature and the secondary chamber fired the gas from the parimary chamber with higher temeprature average 1000-1200 or more to 1600 degree. afterburnning is smoke scrubber with dry or wet scrubber system. incinerator is top […]