Item Specification Model YD-20C Main Product List   Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy oil burner: 02 sets Oil Tank: 100Liters   Optional: Mobile Trailer for Incinerator Phone: +86-13813931455(whatsapp/wechat)Website: http://oeoes.com/waste/  Email: [email protected][email protected]   Nanjing Clover Medical Technology Co.,Ltd. bio medical waste management ppt 2020 HICLOVER Incinerator/Parts Range Main Feature Medical […]
Items/Model TS250(PLC) Picture Principle Waste Incineration Treatment Burn Rate Average 250 kg/hour Feed Capacity Average 400kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2000L Internal Dimensions 210x88x110cm Secondary Chamber 1000L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 2.0Kw Oil Consumption (kg/hour) Average 24.2(DO) Gas Consumption (m3/hour) *** Temperature Monitor Digital Display […]
Q: what is kind of waste can use in this equipment?A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any  explosive and radiation material, liquid waste and gas waste. Q: Incinerator Smoke StandardA: China Government Standard: No.GB18484-2001. Q: Treatment capacityA: Average Capacity calculated by medical waste(lower calorific power (L.C.P): 3.0TH Kcal/Kg per hour),  not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity.   Clover incinerator use time per day up to 24 hours. Between each feed/combustion time,  there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion  time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to use.  Generally, we proposal small laboratory, small clinic use capacity under 20 kgs per hour.  When incinerator use in hospital, please calculate the waste output capacity around 2kgs  per people per day. If there are 200 sickbed in the hospital, that’s mean you need one  incinerator capacity around 400kgs per day, change to capacity per hour is around 30-40 kgs  per hour. According the operation time per day, waste material, budget,  development, etc, you can use capacity from 30-50 kgs per hour incinerator.*How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste. Q: Assembly and TestingA: We supply all documents and incinerators easy to installation and operation. Customer  can send people come to our factory to learn installation and operation. Generally,  We do not send engineer to local site if not request. The dispatch cost is extra according to order. Q: Combustion TemperatureA: The first combustion chamber: 800-1000 centi degree.The second combustion chamber: 1000-1200 centi degree. Q: Incinerator Control ModeA: Default Control mode is common control case. PLC mode according to model and order. Q: Operation and maintenance costsA: Operation cost according to fuel consumption rate and power/staff, etc.  Annual around $500-$1000usd per year maintenance according model, use situation.  One person can service 02 unit incinerators. The staff should have basic electrician  knowledge to operate/inspect/maintaince incinerator/burner/blower according to  operation user guider, and know risk of medical waste to protect worker self with necessary protection element. Q: The Residency time in secondary combustion chamber A: 02 sec. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: oeoes.com/waste  Email: [email protected][email protected]   Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour […]
  Incinerator Items/Model HICLOVER TS30(PLC) Burn Rate (Average) 30-50 kg/hour Feed Capacity(Average) 60kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 330L Internal Dimensions 75x75x60cm Secondary Chamber 180L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V 2P Power 0.5Kw Burner Type Italy Brand Oil Consumption (kg/hour) 12 N.Gas Consumption (m3n/hour) 9.8–20 Temperature Monitor Yes Temperature […]
Mobile Containerized Waste Incinerators pets or human cremation emergency use   Model CA-200 Picture Burning Rate Average 100 kgs/hour Primary Combustion Chamber 2000 Liters Secondary Combustion Chimney Yes Feed Mode Manual Voltage 220V Power 3.0 Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) Average 53 kg/hour Internal Dimensions 200 x 100 x […]
Key Features: — Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator,  General Municipal Solid Waste Incinerator, Pet and Animal Cremation, Containerized Mobile Incinerator,  High Efficient Environmental Waste Incinerator. — Single combustion chamber, double combustion chambers, three combustion chambers and  multi-combustion chambers waste incinerators. — System solutions for medical waste environmental. — […]
Model CA100 Picture Waste Treatment Medical Waste Incineration Treatment Feed Capacity Average 100-200 kgs per feed Burning Rate Average 100-120 kgs per hour Burning Time per Feed Average 1-2 hour Control Mode PLC(Programmable Logic Controller Incinerator) Voltage 220V Power 1.0Kw Fuel Diesel oil Burner Italy Burner Feed Mode Manual Temperature Monitor Digital Display Fuel consumption […]
Model YD-150 Burning Rate Average 150 kgs/hour Feed Capacity Average 300 kgs/feeding Primary Combustion Chamber 1500 Liters Secondary Combustion Chamber 500 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V/380V Power 1.03Kw Fuel Type Diesel Oil/ Natural Gas/LPG Burner Italy Original Oil Consumption (Diesel Oil) 17–36 kg/hour Gas Consumption (Natural […]
Zhangjiagang Tengxiang Machinery Co., Ltd. Mobile: 0086-13962221749(whatsapp) Wechat: chncheumg Email: [email protected]  Face Mask Machine for Coronavirus Disease COVID-19 Technical Parameter: Ø Function: To Produce non woven face mask blank body automatically, including Inerting nose wire, forming, Sealing and cutting finished mask blank. Ø Power supply: 380V/50Hz or 220V mono phase 3.3KW Ø Mask Size: 175mm*80-100mm (two or three layers) […]
Waste is thermally decomposed in the primary chamber at temperatures of 800 °C +. The resulting gaseous products are completely oxidized in the secondary chamber at higher temperatures with sufficient resident time. Other specifications are as follows. A combustion chamber of waste: * Perfectly tight door for the manual loading of waste. The loading should be […]
Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy oil burner: 02 sets Oil Tank: 150Liters Mobile Trailer for Incinerator Model YD-50C Burning Rate (kgs/Hour) Average 20-50 kgs/hour Feed Capacity (kgs) Average 80 kgs/feeding Equipment Weight 2500 kgs(Incinerator) Primary […]
Incinerator Items/Model HICLOVER YD30(PLC)     Burn Rate (Average) 15kg/hour Feed Capacity(Average) 40kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 360L(0.36M3) Internal Dimensions 100x60x60cm Secondary Chamber 200L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V  Power 0.5Kw Burner Type Italy Brand Oil Consumption (kg/hour) 12 N.Gas Consumption (m3n/hour) 9.8–20 Temperature Monitor Yes Temperature Thermometer […]
N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set l Dimension(L*W*H): 1037*855*1780 l Power Supply 15.3kw mono phase l Net Weight: approx.: 1500kg HICLOVER – Medical Environmental    WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet Animal Cremation Solid Waste Incinerator Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: oeoes.com/waste  Email: [email protected][email protected]   Nanjing Clover Medical Technology Co.,Ltd. […]
Items/Model TS50(PLC) Picture Principle Medical Waste Incineration,dual chamber incinerator Burn Rate 50-100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) average 16.9 Gas Consumption (m3/hour) average 20.2 Temperature Monitor Digital Display Temperature Protection Yes […]
Medical waste is posing a growing problem all over the world, jeopardizing the health of staff, patients, disposal workers and anyone else coming into contact with the often hazardous materials discarded by hospitals and other healthcare sites. Hospital waste varies from site to site and the biggest challenge is to dispose of this wide range […]
HICLOVER Incinerator/Parts Range Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion Chambers Single Combustion Chamber Small, Cheap,10-20kgs/Hr. Three Combustion Chambers(Optional) 3 Chambers for high risk waste Pet Cremation Equipment For Pet(small/big) Cremation Business Animal Incineration Equipment For other animal incineration Temperature Control, Primary and Secondary Stoking tools Stainless Steel Spark Screen Primary Chamber Door Locking System HICLOVER Solution for Fighting COVID-19, with ISO9001:2015/CE(2006/42/EC,2014/30/EU) Certification. 1. Medical Waste Incinerator(Containerized […]
Incinerator burn medical and bio waste Items/Model TS100(PLC) Picture   Principle Medical  Waste Incineration Treatment Burn Rate Average 100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes(Dry Scrubber) Feed Mode Manual Voltage 220V/380V Power 0.7Kw Oil Consumption (kg/hour) average 20.4 Gas Consumption (m3/hour) *** […]
Curing Duration,need a small incinerator, they discard 100 liters of covid masks daily.batch load, direct fire,  mobile incinerator for a variety of applications including medical waste. The unit is one of the lightest in its class ,  facilitating deployment for virus outbreaks and disaster relief operations. Primarily running on diesel 1. Where can I watch a video of a real-life application? 2. The modulating under air burners ensure consistent high temperatures needed to destroy infectious waste,  whilst retaining the flue gas for sterilization. Simply load waste into the chamber, close the door and turn on the unit. 3. When approved and paid for, how many days for shipment? 4. As per the requirement we have ordered an Incinerator that can process 100kg hospital waste and as per the  end user they are only able to put 3 bags of waste which are approximately 10kg each. So we are only able to  process 30 Kg of waste instead of 100Kg. As per the hospital the chamber volume is very small and can not process 100kg hospital waste 5. Can you give me the listing of extras needed, and  installation of the TS150 PLC Incinerator and am in  need of technical assistance? 6. What are the most commonly needed repair parts?a)   Waste Auto Loading Ram Hopper  b)   Standard Tools (What the tools are there?, Please figure out) c)   Recommended spare parts (1 year) (such as burner, refactor cement, temperature probe, etc.) d)   Commissioning and Training  e)   Support wires, clamp and bracket as chimney is 33 m height              HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification. Auto. Control Waste Incinerator & Auto. Roll Air Filter(Air Purification)   Waste Incinerator RFQ(Request for Quotation) http://oeoes.com/waste/ad/rfq/   EStore for Waste Incinerators http://www.haiwos.com   2022-06-24 […]
Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production  Shipping Volume Shipping Weight Delivery Location TS30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks 5 m3 3000 kgs Shanghai Port TS50 average 50kgs per hour Average 250 SickBed Diesel Oil 1 set […]
Sources of Healthcare Waste •Hospitals •Clinics •Laboratories •Research activities •Nursing homes •Acupuncturist •Paramedic and ambulance services •Animal research •Blood banks • Mortuaries •Autopsy centers Other Sources of Healthcare Wastes •Physicians’ offices •Dental clinics •Chiropractors •Psychiatric hospitals •Cosmetic piercing and tattooing •Institutions for disabled persons •Funeral services •Home healthcare •Define healthcare waste •Describe sources and examples of healthcare waste •Describe general characteristics of healthcare waste •Identify where wastes are generated in your facility •Categorize the wastes into two general categories based on whether or not they pose a risk •Describe general characteristics of the wastes Definition of Healthcare Waste What is healthcare waste? – Total waste stream from major healthcare establishments and from minor scattered healthcare activities General Types of Healthcare Waste Healthcare waste can be –Non-hazardous general wastes comparable to domestic waste (75-90% of healthcare waste in a health facility) –Potentially hazardous waste or waste that is associated with some health risks (10-25% of healthcare waste in a health facility) Sources of Healthcare Waste •Hospitals •Clinics •Laboratories •Research activities •Nursing homes •Acupuncturist •Paramedic and ambulance services •Animal research •Blood banks • Mortuaries […]
what’s the incinerator of hospital pictures and drawings? if you want to build or buy new incinerator for hospital, confirm the waste capacity per day, like 100kgs per day or more and working time per day, like 10 hours and the capacity of incinerator is average 10kgs per hour and best to buy 10-20kgs per hour incinerator.   we supply […]
Medical Waste Incinerator Capacity: average 50-100 kgs per hour Items/Model TS50(PLC) Picture   Principle Medical Waste Incineration  Burn Rate Average 50-100 kg/hour Feed Capacity Average 100kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) average 16.9 Gas […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://oeoes.com/waste/  Email: [email protected][email protected]   Nanjing Clover Medical Technology Co.,Ltd. HICLOVER is now offering a full range of medical waste incinerators, designed to provide efficient waste destruction, utilizing best available technologies and environmentally friendly process. Due to the secondary chamber with its 2 second retention period, our medical incinerator range is well suited to process medical waste.   Our products ensure […]
medical waste incinerator iraq price HICLOVER TS10 PLC 10kgs per hour Items/Model TS10(PLC) Picture   Burn Rate Average 10 kg/hour Feed Capacity Average 20kg/feeding Control Mode Programmable Logic Controller(PLC) Panel Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.5Kw Oil Consumption (kg/hour) average 8.4kg/hour Gas […]
Items/Model CA100 Picture Principle Medical Waste Incineration Treatment Burn Rate Average 100 kg/hour Feed Capacity Average 200kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 1.3 Kw Oil Consumption (kg/hour) Average 20.4 Kgs/Hour Gas Consumption (m3/hour) *** Temperature […]
small scale municipal solid waste inceneration technologies including key  point is high temerature combustion. the chamber made with heavy duty refractory material,   we fix oil or gas burner to direct fire and auto control the system.    HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.   Medical Waste Incinerator & Auto Roll Air Filter(Air Purification)   What do hospitals do with human waste? When the medical waste is removed from facilities, it is then disposed of in a manner that is safe for the environment. In the past, medical waste would simply be sent to a landfill for disposal. Now a days, it is sterilized and recycled before heading to a special sanitary landfill. What are the 4 major types of medical waste? There are generally 4 different kinds of medical waste: infectious, hazardous, radioactive, and general.   Nanjing Clover Medical Technology Co.,Ltd. materials not recommended for incineration incinerator bin ram price of an incinerator waste management companies in lusaka incinerator for sale garden waste incinerator medical waste disposal pdf incenetor incinerator bin Items/Model […]
HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like […]
Dual heat burners and dual chamber incinerator Burning capacity up to 30 Kg per hour Main Product List Primary Combustion Chamber(Main body stainless steel) Secondary Combustion Chamber(Main body stainless steel) Mix-Combustion Chamber Wet Scrubber( Washing Tower)(Main body stainless steel) Incinerator Control Case Chimney:5.0Meters  Stainless Steel Italy gas burner: 02 sets Oil Tank (if oil fuel): […]
Items/Model TS50(PLC) Picture Principle Solid Waste Incineration Burn Rate 30-45 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Oil Consumption (kg/hour) Average 13.3 Gas Consumption (m3/hour) *** Temperature Monitor Digital Display Temperature Protection Yes Oil Tank 800L Feed […]
Incinerator Model A1500, Overview This model is big-scale animal cremation equipment for big animals.  Construction is dual/double combustion chamber with 03 units oil/gas burner,  batch load incineration equipment. Animal feed chamber is 1500Liters (Model: A1500).  Primary & Secondary combustion chambers and included mix-combustion chamber,  smoke filter chamber with firebrick and Refractory Concrete chamber. Batch load […]
Combustion Chamber:  · Horizontal cylindrical design  · Inner surface carried out with first-rate refractory material, high temperature proof,  · Combustion chamber volume; 5,3 approximately.  · 1 No. loading door set on the frontal edge of the burning chamber, having a whole section  crossing, suitable to load the Hospital waste material and to unload the ashes.  · Burner capacity (under full power) 30-40 Kg/ Hour approximately  · Operating Temperature: 700-900 cXC or better  · Standard Color: Black  HICLOVER YD30(PLC) 30-50 kg/hour 60kg/feeding PLC Automatic 360L(0.36M3) 100x60x60cm 200L Yes Manual 220V 2P 0.5Kw Italy Brand   Mobile: +86-138139 31455(WhatsApp) Website: oeoes.com/waste   Email:     [email protected]        Email:    [email protected]    
you have to do custom clearance your side. and shipping document with bill of lading, invoice, packing list only. we have incinerator in PK and AFG but iam not sure where it is. all incinerator passed EU CE and ISO. if natural gas or LPG fuel, you have to contact with local gas supplier to […]
Incineration plant machine of 150kg/hr On Lpg Items/Model TS150(PLC) Picture   Principle Medical Waste Incineration Treatment Burn Rate Average 150 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1500L Internal Dimensions 150x100x100cm Secondary Chamber 750L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.9Kw Oil Consumption (kg/hour) Average 24.2(D.O) Gas Consumption (m3n/hour) Average 21.3(LPG) Temperature […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://oeoes.com/waste/  Email: [email protected][email protected]   Nanjing Clover Medical Technology Co.,Ltd. Capacity: Average 300 kgs per hour Model YD–300 Picture   Burning Rate Average 300 kgs/hour Feed Capacity Average 500 kgs/feeding Primary Combustion Chamber 2400 Liters Secondary Combustion Chamber 1200 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Wet Scrubber System(3 Section Type) Feed Mode Manual Voltage 380V Power 12.0 Kw Fuel Type […]
Vertical closed furnace combustion chamber incinerator   Medical waste, disposable syringes, infusion sets processing, cotton yarn, the operating room, the residual limb, waste rubber gloves, protective clothing and infectious and harm venereal hospital bed supplies, general wastes.   10-20kg/time (daily burn 3-6times, each time consume about 1 hour) total daily waste capacity 120 kg   Incinerator Items/Model HICLOVER TS10(PLC)   Burn Rate (Average) 10-20 kg/hour Feed Capacity(Average) 20kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V 2P Power 0.5Kw Burner Type Italy Brand Oil Consumption (kg/hour) […]
30kgs per hour(average) medical waste incinerator, design dual  combustion chambers(primary chamber and secondary chamber),  smoke filter chamber, PLC auto. control system, 0.33m3(330liters) primary combustion chamber, italy oil or gas fuel burner. for small  hospital medical waste treatment. Buy waste incinerator, find hiclover Items/Model TS30 PLC Principle Waste Incineration Burn Rate Average 30kgs/hour Fuel Type Diesel Oil/Natural […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://oeoes.com/waste/  Email: [email protected][email protected]   Nanjing Clover Medical Technology Co.,Ltd. HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project. HICLOVER Incinerator/Parts Range Main Feature Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion Chambers Single Combustion Chamber Small, Cheap,10-20kgs/Hr. Three Combustion Chambers(Optional) 3 Chambers for high risk waste Pet Cremation Equipment […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://oeoes.com/waste/  Email: [email protected][email protected]   Nanjing Clover Medical Technology Co.,Ltd. Items/Model TS30(PLC) Picture   Burn Rate Average 30-50 kg/hour Feed Capacity Average 60kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 330L Internal Dimensions 75x75x60cm Secondary Chamber 180L Smoke Filter Chamber Yes Feed Mode Manual Feeding Voltage 220V Power 1.0 Kw Oil Consumption (kg/hour) Average 13.3 Gas Consumption (N.G, m3n/Hour) *** Gas Consumption […]
Item Specification Model YD-30C Main Product List Primary Combustion Chamber(Main body stainless steel) Secondary Combustion Chamber(Main body stainless steel) Mix-Combustion Chamber Wet Scrubber( Washing Tower)(Main body stainless steel) Incinerator Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy gas burner: 02 sets Oil Tank (if oil fuel): 100Liters Automatic PLC controller incinerator plant with […]
BURNING RATE : -100-150kgs per hour MINIMUM OPERATING TEMPERATURE : 800-1000 oC ( PRIMARY COMBUSTION ) MAX OPERATING TEMPERATURE : 1000-1200 oC ( AFTER BURNER COMBUSTION ) SECONDARY BURNING CAPACITY : COMPULSORY DENSITY INSULATION : 50 mm high Refractory capacity : min 114mm HEAVY DUTY REFRACTING LINING TO WITHSATND 17500C AVEARGE BURN OUT TIME : […]
Advantages of Waste Incineration     Decreases Quantity of Waste. …     Efficient Waste Management. …     Production of Heat and Power. …     Reduction of Pollution. …     Incinerators Have Filters For Trapping Pollutants. …     Saves on Transportation of Waste. …     Provides Better Control Over Odor […]
This equipment quality structural for kinds of site, like hospital, environmental department,  animal cremation agencies, etc.  HICLOVER Incinerator supply updated models with dual combustion chamber,  mix-combustion chamber and smoke filter  chamber with refractory lines, and the combustion chamber temperature up to 1200 deg C. Equipment Technical Specifications Model YD-10C Picture Feed Capacity Average 40 kgs […]
Oil tank with 2000Liters capacity Items/Model TS150(PLC) Picture Principle Waste Incineration Treatment Burn Rate Average 100-150 kg/hour Feed Capacity Average 750kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Main Body Steel 8mm thickness Chamber Material High Alumina Fire Brick Wall, 1750℃ Rate Paint for outside face 800°C Rate Combustion Chamber 1570L Internal Dimensions 150x100x105cm Secondary Chamber […]
Item Specification Model YD-30C (customer made model) Main Product List Primary Combustion Chamber(Main body stainless steel) Secondary Combustion Chamber(Main body stainless steel) Mix-Combustion Chamber Wet Scrubber( Washing Tower)(Main body stainless steel) Incinerator Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy gas burner: 02 units Oil Tank (if oil fuel): 100Liters Model YD-30C Feed […]
HICLOVER – Containerized Mobile Incinerator Medical Waste Incinerator Model CA50 Model CA50 Picture Waste Treatment Medical Waste Incineration Treatment Feed Capacity Average 100 kgs per feeding Burning Rate Average 50 kgs per hour Burning Time per Feed Average 2 hour Control Mode PLC(Programmable Logic Controller Incinerator) Voltage 220V Power 1.0 Kw Fuel Diesel oil Burner Italy […]
Light Weight Small-Scale Medical, Mobile Optional Type Model YD-30  Picture   Burning Rate  average 30 kgs/hour Feed Capacity average 40 kgs Paimary Combustion Chamber 200 Liters Secondary Combustion Chamber 100 Liters Mix Combustion Chamber Yes Feed Mode Manual Voltage 220V Power 0.59Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) average 13.3 […]
we produce incinerator for the waste incinerator for covid19 ppe waste, small capacity is 5-10kgs per hour powered by diesel oil.   high temeprature combustion chamber and after burn secondary chamber to burn the smoke.    Mobile: +86-138139 31455(WhatsApp)   Medical waste (trash) coming from healthcare facilities treating COVID-2019 patients is no different than waste coming from facilities without COVID-19 patients. […]
there was one set oil fired incinerator send to Kenya. average capacity 30-50kgs per hour for small hospital.   if you have any requirement, please send technical details such as capacity(kgs/hour or day), diesel oil or natural gas, etc, we will support for best incinerator and price.   Mobile: +86-138139 31455(WhatsApp)   Nanjing Clover Medical […]
we supply incinerator for Kenya, with IDF SGS certification. the HS code of incinerator is 84178050. if you are looking for incinerator suppliers in kenya. please contact with us. we supply 10kgs per hour to 1000kgs per hour waste incinerators, with or without wet scrubber system. the burner is oil or gas type. We service and maintain our incinerators and provide consultancy services to Consulting Engineers, Mines, Abattoirs and Hospitals,  giving full details on the incinerator required and the price.   1. General waste incinerators for sale in Kenya. 2. Pet Cremation incinerators supply in Kenya 3. Bio-Medical Incinerators in Kenya […]
Coronavirus Disease 2019 (COVID-19) pandemic continues all over the world, clinics,hospitals,goverment may need to consider on-site disposal for the infectious  medical waste. The medical waste incinerators that has been effectively used to dispose of hazardous waste during  viral outbreaks like Ebola. HICLOVER.COM reaches temperatures of up to 1200oC and is able to destroy health care […]