Day: February 13, 2023

Q: what is kind of waste can use in this equipment?A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any  explosive and radiation material, liquid waste and gas waste. Q: Remedy capacityA: Average Capacity calculated by medical waste(lower calorific power (L.C.P): 3.0TH Kcal/Kg per hour),  not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity.   Clover incinerator use time daily to 24 hours.  Between each feed/combustion time,  there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion  time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to use.  Generally, we proposal little lab, little clinic use capability under 20 kgs per hour.  When incinerator use in hospital, please calculate the waste output capacity around 2kgs  per people per day. If there are 200 sickbed in the hospital, that’s mean you need one  incinerator capacity around 400kgs per day, change to capacity per hour is around 30-40 kgs  per hour. According the operation time per day, waste material, budget,  development, etc, you can use capacity from 30-50 kgs per hour incinerator.*How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste. Q: Assembly and TestingA: We provide all documents and incinerators simple to setup and operation.  Customer  can send people come to our factory to learn installation and operation. Generally,  We do not send engineer to local site if not request. The dispatch cost is extra according to order. Q: Combustion TemperatureA: The first combustion chamber: 800-1000 centi degree.The second combustion chamber: 1000-1200 centi level. Q: Incinerator Control ModeA: Default Control mode is common control case.  PLC mode according to order and model. Q: Operation and maintenance costsA: Operation cost according to fuel consumption rate and power/staff, etc.  Annual around $500-$1000usd annually care according model, use scenario.  One individual can service 02 device incinerators.  The team should have basic electrician  knowledge to operate/inspect/maintaince incinerator/burner/blower according to  operation user guider, and know risk of medical waste to protect worker self with necessary protection element. Q: The Residency time in secondary combustion chamber A: 02 sec. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: oeoes.com/waste  Email: [email protected]Email: [email protected]   Items/Model […]
CO – Shouldn’t exceed 100 mg/m3 SO2 – Shouldn’t exceed 400 mg/m3 HF – (Hydrogen fluoride) Shouldn’t exceed 9.0 mg/m3 NO2 – Shouldn’t exceed 500 mg/m3 Smoke dust  – Shouldn’t exceed 100 mg/m3 9    Height of the Incinerator – less than 10m above ground level 10    Manufacturer’s Warranty – less than 1 year 11    Electrical […]