Quelling system/Heat exchanger Have to be made and generated from anti rust and acid assault goods such as stainless-steel 316 or comparable.
Chemical application It should be equiped with the correct autochemical application system to deal with the pH for the water of the wet scrubber system such as picking up systems.
Retention time Of the stream gases not less than two Sec from the hot component.
Thorough illustrations, publications should be included.
Capacity Not less than 500Kg/hr.
Extra Oxygen focus Of key burning chamber 3-6% max.
Control Area has to be equiped with a controller board reveals Temp. Of the burning heaters, gas monitoring, digital Temperature level. Indecation for the primary/secondary chambers, electronic Temperature. Indication for the gases … … and so on it should surely be also Car process, burnures on/off vehicle lights switch, auto start/stop for air discharge control system, automobile gas constant security system analysis as well as print from gas exhaust specs…… … … and so on. A/c System The primary chamber ought to be provided automobile cooling systemthrough nozzles to allow direct air conditioning if the Temperature. If the burning Temperature, will definitely be heigher than 1100 C.
Temperature. Burning chamber 800-1000 C.
Secandry combustion burning 1000-1200 C, with the possibility to be updated to 1400 C.
Feeding System Must be vehicle feeding system into primary chamber.
. The quote should included checklist of initial added elements for 7 decades.
Burning chamber two burning chamber.
Inter-lock system The incinerator burner needs to equiped with inter-lock system to prevent quit the waste to the key chamberTemperature level less than 500 C.
The burner should be set inside closed appropriate structure with fantastic oygenation as well as air circulation system. Auto cleansing system for trucks and likewise waste containers, as well as also great storage location…… … … and more{
(adsbygoogle = window.adsbygoogle || []).push({});|}
Chimney It need to be perfect with the capacity along with the technological requirements, with elevation not less than 12m from floor degree. With easy opennable tasting factor equivalent concerning 3 inch, and also the optimum tasting places goes to the very least 8D downstream instructions as well as also 2D upstream from any kind of kind of stream disturbancies.
Doors Need to be lined with the similar bricks, as well as the sides lined with distinct excellent shielding item to remain clear of any kind of kind of gas running away, as well as also the doors should be kept under negative tension and anxiety throughout the operation.
Comments are closed