Double chamber medical infectious waste incinerator
10-50 kg per hour
Treatment of infectious waste, sharps and small amounts of pathological waste.
The following average characteristics are considered*:
•heating value above 2000 kcal/kg (8370 kJ/kg);
•content of combustible matter above 60%;
•content of non-combustible solids below 5%;
•content of non-combustible fines below 20%;
•moisture content below 30% by weight
The medical waste incinerator shall be capable of reducing waste to ash not exceeding
10% in weight of the total combustible charges and below 1% in volume of the original waste.
The medical waste incinerator will be installed outdoors. All incinerator components
shall be suitable for but not limited to outdoor shaded installation, including electric motors, be resistant to corrosion, moisture and related weather elements.
Static stability of the incinerator must be achieved by a steel frame on which the incinerator doors, the burner and the protective shielding are mounted

Incinerator Items/Model

HICLOVER TS50

Burn Rate (Average)

10-50kg/hour

Feed Capacity(Average)

50kg/feeding

Control Mode

PLC Automatic

Intelligent Sensor

Continuously Feeding with Worker Protection

High Temperature Retention(HTR)

Yes (Adjustable)

Intelligent Save Fuel Function

Yes

Primary Combustion Chamber

560L

Internal Dimensions

100x80x70cm

Secondary Chamber

280L

Smoke Filter Chamber

Yes

 

Model

TS50

Main Product List per 01 set

Primary Combustion Chamber

 

Secondary Combustion Chamber

 

Smoke Filter Chamber

 

Incinerator PLC Control Case

 

Chimney:6.0Meters

 

Italy oil burner: 02 units

 

Oil Tank (if oil fuel): 200Liters

 

 


 