Q: What’s kind of waste can use within this equipment? A: This equipment to medical waste, pet animal, Municipal waste, reside waste. Prohibit any volatile and radiation substance, liquid gas and waste waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001.
Q: Treatment capacity A: Typical Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour)doesn’t indicate any waste material. The animal/pet combustion rate around 2/3 of average capacity.
Clover incinerator use time per day up to 24 hours. Between every feed/combustion time, there are about 0.5-1 hours cooling time plus time to get feeding squander. Burning incenrator manufactuer, burning medical waste, burning waste chamber, purchase a portable crematorium, purchase a little incinerator, purchase creature cremation systems, Actual combustion time per day is about 16 hours. The life of incinerator involving 5-10 year according to use.
Generally, we proposal little lab, little clinic use capability under 20 kgs per hour. When incinerator use in hospital, please compute the waste output around 2kgs per individuals every day. If there are 200 sickbed in the hospital, that’s imply you need 1 incinerator capability around 400kgs every day, change to capacity per hour is approximately 30-40 kgs per hour. According the operation time every day, waste material, funding, development, etc, you can use capacity from 30-50 kgs per hour incinerator. *How to compute Animal Cremation Burn Rate: 2/3 of this medical waste.
Q: Meeting and Testing A: We supply all files and incinerators easy to setup and functionality. Client can send individuals visit our factory to find out operation and installation. Generally, We do not send engineer to neighborhood website if not request. The dispatch price is extra according to order.
Q: Combustion Temperature A: The first combustion chamber: 800-1000 centi degree.
Q: Incinerator Control Mode A: Default Control mode is common control instance. PLC mode according to model and order.
Q: Operation and maintenance costs A: Operation price according to fuel consumption rate and power/staff, etc.
Annual approximately $500-$1000USD per year maintenance according model, use situation.
One individual can service 02 unit incinerators. The staff should have basic electrician understanding to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know threat of medical waste to protect worker self with essential protection element.
Q: The Residency time in combustion chamber A: 02 sec.
Items/Model | YD-10C | YD-20C | YD-30C | YD-50C |
Burning Rate (kgs/Hour) | 10 kgs/Hr. | 20 kgs/Hr. | 30 kgs/Hr. | 50 kgs/Hr. |
Feed Capacity (kgs) | 40 kgs | 40 kgs | 50 kgs | 80 kgs |
Equipment Weight | 1200 kgs | 1200 kgs | 1800 kgs | 2200 kgs |
Primary Chamber (Liters) | 200 | 200 | 250 | 400 |
Secondary Chamber (Liters) | 140 | 140 | 140 | 140 |
External Dimensions (cm) | 170x140x160 | 170x140x160 | 170x140x190 | 180x160x200 |
Internal Dimensions (cm) | 55x55x65 | 55x55x65 | 55x55x85 | 70x70x85 |
Oil Tank(Liters) | 50 | 100 | 100 | 150 |
Door Opening (cm) | 38 x 48 | 38 x 48 | 38 x 48 | 45×55 |
Chimney (M) | 5 | 5 | 5 | 5 |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Secondary Chamber | YES | YES | YES | YES |
Mix-Combustion Chamber | YES | YES | YES | YES |
Smoke Filter Chamber | YES | YES | YES | YES |
Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Temperature Monitoring | YES | YES | YES | YES |