Basic Info.
Product Description
Technology Respond(FAQ)
Q: What is kind of waste can utilize in this equipment? A: This gear for medical waste, pet animal, Municipal waste, live squander. Prohibit any explosive and radiation material, liquid waste and gas waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001.
Q: Treatment capacity A: Typical Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not indicate any waste material. The animal/pet combustion rate around 2/3 of average capacity.
Clover incinerator use time per day up to 24 hours. Between every feed/combustion time, there are approximately 0.5-1 hours cooling time and time for feeding waste. Medical waste, medical waste incinerator china, pet incineration equipment, pet incinerator available, portable incinerator manufacturers, waste incinerator manufacturers from china, Actual combustion time per day is around 16 hours. The life of incinerator between 5-10 year based on use.
Generally, we proposition small lab, small clinic use capacity under 20 kgs per hour. When incinerator use in hospital, please calculate the waste output capacity around 2kgs per people each day. If there are 200 sickbed in the hospital, that's mean you need 1 incinerator capacity around 400kgs each day, change to capacity per hour is around 30-40 kgs per hour. According the operation time per day, waste material, budget, development, etc, you may use capacity from 30-50 kgs per hour incinerator. *How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Testing and Assembly A: We supply all documents and incinerators easy to installation and operation. Client can send people come to our factory to learn installation and operation. Generally, we don’t send engineer to local site or even request. The dispatch cost is additional according to order.
Q: Combustion Temperature A: The first combustion chamber: 800-1000 centi level. The second combustion chamber: 1000-1200 centi level.
Q: Incinerator Control Mode A: Default Control manner is common control instance. PLC mode according to model and order.
One individual can service 02 device incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower based on performance user guider, and know risk of medical waste to safeguard worker self with essential protection element.
Q: The Residency period in secondary combustion chamber A: 02 sec.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |