incineration Heater for burning patalogical (such as human blood or tissue ) as west
The weight of this west stuff is 700 kg per month and we need an isolated heating system
Without fume in addition to any sort of damaging gasoline
. INCINERATOR SPECIFICATION
# Summary Specification
1 Burning Capacity – – 400 kg/time and must not be much less than 300 kg/time. Optimum combustion time have to be 6 times/day
2 Smokeshaft outside diameter – – 300 to 400 millimeter
3 Fan power – – Need to not exceed 1.1 kw
4 Voltage – – 220V
5 Oil consumption – – Have to not exceed 14kg/h
6 Feeding door diagonal dimension (mm) – – Not less than 500mm 7 Incineration Temp. (⁰ C) – – 800 or over 8 Exhaust
Carbon Monoxide – – Shouldn’t go beyond 100 mg/m3
SO2 – – Need to not go beyond 400 mg/m3
HF – – (Hydrogen fluoride) Shouldn’t exceed 9.0 mg/m3
NO2 – – Should not exceed 500 mg/m3
Smoke dirt – – Need to not exceed 100 mg/m3
9 Elevation of the Burner – – Not much less than 10m over ground level
10 Maker’s Service guarantee – – less than 1 year
11 Electrical Connection – – From closest flow box using 25mm2 electrical cable along with all relevant connections and circuitry