Medical Waste Incinerator in Stock for Coronavirus Disease COVID-19

HICLOVER Medical Waste Incinerator in Stock(Finished and Semi-finished and New Production) Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production  TS30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks TS50 average 50kgs per hour Average 250 SickBed Diesel Oil 1 set 7 … Read more

Incinerators QA

Q: what is kind of waste can use in this equipment?A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any  explosive and radiation material, liquid waste and gas waste. Q: Remedy capacityA: Average Capacity calculated by medical waste(lower calorific power (L.C.P): 3.0TH Kcal/Kg per hour),  not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity.   Clover incinerator use time daily to 24 hours.  Between each feed/combustion time,  there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion  time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to use.  Generally, we proposal little lab, little clinic use capability under 20 kgs per hour.  When incinerator use in hospital, please calculate the waste output capacity around 2kgs  per people per day. If there are 200 sickbed in the hospital, that’s mean you need one  incinerator capacity around 400kgs per day, change to capacity per hour is around 30-40 kgs  per hour. According the operation time per day, waste material, budget,  development, etc, you can use capacity from 30-50 kgs per hour incinerator.*How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste. Q: Assembly and TestingA: We provide all documents and incinerators simple to setup and operation.  Customer  can send people come to our factory to learn installation and operation. Generally,  We do not send engineer to local site if not request. The dispatch cost is extra according to order. Q: Combustion TemperatureA: The first combustion chamber: 800-1000 centi degree.The second combustion chamber: 1000-1200 centi level. Q: Incinerator Control ModeA: Default Control mode is common control case.  PLC mode according to order and model. Q: Operation and maintenance costsA: Operation cost according to fuel consumption rate and power/staff, etc.  Annual around $500-$1000usd annually care according model, use scenario.  One individual can service 02 device incinerators.  The team should have basic electrician  knowledge to operate/inspect/maintaince incinerator/burner/blower according to  operation user guider, and know risk of medical waste to protect worker self with necessary protection element. Q: The Residency time in secondary combustion chamber A: 02 sec. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: [email protected]Email: [email protected]   Items/Model … Read more

incineration Furnace for burning patalogical

CO – Shouldn’t exceed 100 mg/m3 SO2 – Shouldn’t exceed 400 mg/m3 HF – (Hydrogen fluoride) Shouldn’t exceed 9.0 mg/m3 NO2 – Shouldn’t exceed 500 mg/m3 Smoke dust  – Shouldn’t exceed 100 mg/m3 9    Height of the Incinerator – less than 10m above ground level 10    Manufacturer’s Warranty – less than 1 year 11    Electrical … Read more

incinerator Model TS150

HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan. We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for incinerator customer, supply medical incinerator, hospital incinerator, animal incinerators, hog incinerators, pet cremation equipment, small incinerator, pet incinerator, animal incinerator, portable incinerator, small animal incinerator, infectious waste pyrolysis machine, laboratory incinerator. HICLOVER help customer reduce purchase budget, custom made function, quality products and friendly service. Medical waste is posing a growing problem all over the world, jeopardizing the health of Patients, Staff, disposal Employees and anyone else coming into contact with the often hazardous materials discarded by hospitals and other healthcare sites.  WWW.HICLOVER.COM|Waste Incinerators WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd..

cytotoxic waste

it’s also very important for us to know whether the unit is qualified to deal with cytotoxic waste and also the characteristics and disposal of treatment residues. Moreover, operational needs in terms of electricity and fuel consumption, as well as especially the off-gas treatment system implemented, bear significant importance, as fulfilling the requirements of Regulation … Read more

HICLOVER INCINERATORS

Medical waste is posing a growing problem all around the world, jeopardizing the health of staff, patients, disposal employees and anyone else coming into contact with the often hazardous materials discarded by hospitals and other healthcare sites. Hospital waste varies from site to site and the biggest challenge is to dispose of this broad range … Read more

HIGH TECH PYROLYTIC MEDICAL WASTE INCINERATOR

HIGH TECH PYROLYTIC MEDICAL WASTE INCINERATOR 1.   21. The de- ashing must be performed in the bottom of the combustion chamber or the deashing Electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating * A timer with flexible temporization for the regulation of every burner. * Carcass in solid sheet steel with support … Read more

Pet Animal Crematory Incineration

Incineration is the most obvious solution for total destruction of municipal waste, avoiding  all the direct and indirect risks associated with other disposal methods.Incineration perfectly fits into a trend of treating waste in a safe way, and if possible, at the  same place where it was generated to avoid cross-contamination risk and to keep waste treatment costs at acceptable level. — Upgrade/Downgrade Burning Rate WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. ※Main Feature:–Three Combustion Chambers or A/B Main Combustion Chamber— Double or Three Italy Burner–Burning Rate: 80-800kgs per hour–Combustion Chamber: 1.0M3-10.0M3※Optional Function/Parts/Material/Burning Rate: — Stainless Steel Chimney — Dry Smoke Filter Chamber— Chimney Height Custom Made— Semi-Automatic Waste Feeding— 3-Section Wet Scrubber System— Movable Platform Feeding Door— Additional Burner Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: [email protected]Email: [email protected]   Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L … Read more