HICLOVER Waste Incinerator 10-500kgs/Hr.Double Combustion Chambers

Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC) Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. Combustion Chamber 1200L 1500L 2000L 3000L Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm Secondary Chamber 600L 750L 1000L 1500L Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber … Read more

Incinerator YD-150 with Stainless Steel Wet scrubber-Cooling Spray tower

Model YD-150 Burning Rate Typical 150 kgs/hour Feed Capacity Average 300 kgs/feeding Primary Combustion Chamber 1500 Liters Secondary Combustion Chamber 500 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V/380V Power 1.03Kw Gas Form Diesel Oil/ Organic Gas/LPG Burner Italy Original Oil Consumption (Diesel Oil) 17–36 kg/hour Gas Consumption (Natural … Read more

Incinerator burn medical and bio waste

Incinerator burn medical and bio waste Items/Model TS100(PLC) Picture   Principle Medical  Waste Incineration Treatment Burn Rate Average 100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes(Dry Scrubber) Feed Mode Manual Voltage 220V/380V Power 0.7Kw Oil Infection (kg/hour) average 20.4 Gas Consumption (m3/hour) *** … Read more

Incineration plant System of 150kg/hr on LPG

Incineration plant machine of 150kg/hr On Lpg Items/Model TS150(PLC) Picture   Principle Medical Waste Incineration Treatment Burn Rate Average 150 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1500L Internal Dimensions 150x100x100cm Secondary Chamber 750L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.9Kw Oil Infection (kg/hour) Typical 24.2(D.O) Gas Consumption (m3n/hour) Typical 21.3(LPG) … Read more

Negozio tiffany milano the whole of Europe has 423 waste incinerators

One of these,tnthe steel industry generated two? English number Is Significantly higher than normal amount of waste incineration. � Rock hillsIncineration plant turned landscapeIn recent decades, with improvements in technology, incineration, waste incineration plants living abroad to implement a large-scale restructuring, through higher ecological standards to change the old incineratoroff a small plant, built manufacturers … Read more

incinerator manufacturers china

we are incinerator manufacturers china with hiclover manufacturer and TS version, YD version incinerators for medical waste, pet crematory, creature incineration and other solid waste treatment. Currently we supply different series for local client requirements and layout updated incinerator with our leading technology. The updated design characteristic of our range of incinerators make them one … Read more

chinese incinerator manufacturers

wea are chinese incinerator makers.  Nanjing Clover Medical Technology Co., Ltd..  Is a leading waste incinerator maker in China. All show comprised burning capability 10kgs per hour, 30kgs per hour,50kgs each hour,100kgs each hour,150kgs each hour,300kgs each hour,500kgs per hour. So far, all versions sale to all around the world and also have good feedback … Read more

Controlled air medical waste incinerator designed for incineration of bio-medical waste

Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc.) Operational Specs Physical Specs Combustion Chamber Volume (m3) 8.80m3 Burn Rate* up to 1,500kg per hour Average Fuel Consumption 65 kg per hour or more (7 diesel burners) Operational Temperature 850 – 1320°C Gas Retention in Secondary Chamber Large secondary chamber     Temperature Monitoring Yes     Average ash residue (%) 3%     Thermostatic Device Yes   1000l diesel flue tank Venture gas scrubber Hydraulic Ram Feeding System Diesel Powered Large Incinerator Minimum Specification Required Standards 1) Bidder or Manufacturer ISO 9001 Certified 2) Respecting international emission standards Electrical characteristics 3) A 230V, 60Hz single-phase electrical source. 4) Protections against over-voltage and over-current line conditions. 5) Compliance with applicable Ghanaian standards and regulations. Operational characteristics 6) Two-stage incineration with dual chamber combustion 7) Burn rate: 15 – 20 Kg/h 8) Capacity: not less than 130 L 9) Concentrations of most pollutants in stack gases below detection limits 10) Diesel fuel 11) Electronic system control 12) Easy to operate and minimal training 13) Any accessory or dedicated device necessary to the proper functioning and utilization of the equipment included PLEASE REFER TO BROCHURES ATTACHED FOR DETAILED SPECIFICATION

Controlled air medical waste incinerator designed for incineration of bio-medical waste

Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc.) Operational Specs Physical Specs Combustion Chamber Volume (m3) 8.80m3 Burn Rate* up to 1,500kg per hour Average Fuel Consumption 65 kg per hour or more (7 diesel burners) Operational Temperature 850 – 1320°C Gas Retention in Secondary Chamber Large secondary chamber     Temperature Monitoring Yes     Average ash residue (%) 3%     Thermostatic Device Yes   1000l diesel flue tank Venture gas scrubber Hydraulic Ram Feeding System Diesel Powered Large Incinerator Minimum Specification Required Standards 1) Bidder or Manufacturer ISO 9001 Certified 2) Respecting international emission standards Electrical characteristics 3) A 230V, 60Hz single-phase electrical source. 4) Protections against over-voltage and over-current line conditions. 5) Compliance with applicable Ghanaian standards and regulations. Operational characteristics 6) Two-stage incineration with dual chamber combustion 7) Burn rate: 15 – 20 Kg/h 8) Capacity: not less than 130 L 9) Concentrations of most pollutants in stack gases below detection limits 10) Diesel fuel 11) Electronic system control 12) Easy to operate and minimal training 13) Any accessory or dedicated device necessary to the proper functioning and utilization of the equipment included PLEASE REFER TO BROCHURES ATTACHED FOR DETAILED SPECIFICATION

Incinerator Primary Combustion Chamber

HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial  trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed. Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and housing structures,  eliminating the man power and costs involved. The system has the added benefit of total mobility (both local and international), and is ideal  for military and civil camps and remote locations where infrastructure is scarce. Incineration is the most obvious solution for total destruction of municipal waste, avoiding all the direct and indirect risks associated with  other disposal methods. Incineration perfectly fits into a trend of treating waste in a safe way, and if possible, at the same place where it was generated to avoid  cross-contamination risk and to keep waste treatment costs at acceptable level. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Website: www.hiclover.com   Email: [email protected] Email: [email protected]