Suitable models for required waste disposal range.
 Combustion efficiently per hour based on 08hrs operation and its fuel category
 installation method C Mobile type/ possibility of structured inside container / structured in permanent base
  Fuel consumption details consisting electricity 
Capacity: 20KG/Hr, Temp Range: 600 Deg. C C 1100 Deg. C 
Fuel Supply: Natural Gas/Diesel
Dual Combustion Chamber Complete Scrubbing System (Dual 
Resultant Gas Washer), Dual Blower, Chimney Height: 8m
Electric Supply: 220/240Volt, Single Phase 
Waste treatment capacity: 35 kg / h
The combustion chamber is thick steel plate (3 to 10 mm ) with reinforcements, specially built .
Front loading with watertight door mounted on hinges, locking screw wheel , flexible gasket and an insulating refractory lined 
.
An internal lining of refractory concrete containing 42% of H2 03 (alumina ) and 100 mm thick walls.
fibrous insulation panels made ??of calcium silicate with a thickness of 75mm .
Automatic Burner ( diesel or gas must be specified in the order ) with flames diving in one piece monoblock with an electronic 
ignition system , permanent ventilation control valve and isolation valve.
combustion floor made ??in carborundum , preventing binding of glass and slag.
Equipped with two (02) chambers
Fuel: Gas or butane gas
Power supply: 220 V 50 Hz single-phase
Capacity 100 Kg (0.18 m3)
Electric starter
・       The room dimensions are 6.64 m width x 6.61 m length x 6.03 m height at lowest point/per one incinerator. Are these 
dimensions sufficient for complete one medical incinerator 150 kg/hours (1.5ton/day).
・       Please, provide complete data about chemical consumption required for waste incineration, gas emission treatment 
,liquid waste and generated soiled wastes handling and/or, treatment .
・       Please, confirm that the exhaust gases are treated by alkaline scrubbing (wet or dry).