Waste calorific worth: 4000KCAL/KG
Moisture Web content: 10-25%.
Small Ability: 50Kg/Hour set load.
Additional Chamber: 2 Secs @ 850degrees C
The main burning chamber must make certain very little separation temperature degree is not much less than 850 degrees C.
INSULATION.
Calcium Silicate.
Restricting Constant solution restriction 1000 degrees C.
Density 25mm
THROUGHPUT.
50kg/hour at a tiny calorific worth of 4,000 kcal/kg as well as an average bulk density of 120kg/MCubed for standard waste as well as 160kg/MCubed for medical care waste.All type of chemicals substances (Biocides) that made use of for Oil procedure sites (water base Exploration, oil operating centers for the corrosion as well as additionally others: The circumstances of the biocides are “WS-36, HAI-85M, SOFT DRINK ASH, DSMA, MICRO MATRIX, CALCIUM CARBONATE PENALTY, BARAKLEAN, GILSONITE, MIXED WASTE DIRT CHEMICALS, ZINC CARBONATE, CAUSTIC SODA, ENVIROTHIN, BARAZAN D,. etc) in addition to the products are solid and fluid.
2. In regards to the quantity of dropping the waste, possibly 200 – – – – 500 kg per human resources.
3. Our Operational time can be in Day in addition to can be during the night.
4. Can you please provide me the expenditure of device operated with Diesel as well as Gas.The primary burning chamber is the major structure of the heater, produced from light steel plate as well as tensed with rolled steel areas. It is brought from the flooring degree on a substantial steel assistance framework. Internally the covering is lined with calcium silicate insulation and additionally a warm face combination of incredibly duty brickwork or high strength castable.
The vital burning chamber must see to it minimum departure temperature level is very little less than 850 ° C
. One Hands-on Lots Incinerator comprising:.
·???????? Guidebook Loading door.
·???????? Horizontal strong fire place, refractory lined main combustion chamber. Approximate dimensions 800 mm dimensions x 2100mm long.
·???????? Complete sized bulk load/ash elimination door.
·???????? 1 off diesel-fired ignition heater– – temperature level managed. ·???????? 1 off shedding air supply fan in addition to distribution system, automated control.
·???????? High capacity additional burning chamber with residence time very little less than 2 secs @ >> 850 ° C. ·???????? 1 off diesel-fired afterburner– – temperature handled.
·???????? Control board– – automated operation.
e????? Temperature level sign key as well as likewise second chambers 0-1200 ° C.
e????? Refractory lined flanged smokeshaft to an elevation of 10M over ground degree